Bio-rad iMark Microplate Absorbance Reader Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Bio-rad iMark Microplate Absorbance Reader. Bio-Rad iMark Microplate Absorbance Reader User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Instruction Manual

iMark™ Microplate Absorbance Reader Instruction Manual

Strona 2

iMark Microplate Absorbance Reader Instruction Manual 4 Keypad Guide Main Returns to MAIN SCREEN. Start/Stop Initiates plate reading using

Strona 3 - Warranty Statement

iMark Microplate Absorbance Reader Instruction Manual 5 Instrument Setup Unpacking the Instrument The shipping carton contains the following

Strona 4 - Regulatory Notices

iMark Microplate Absorbance Reader Instruction Manual 6 4. Install the printer paper. The thermal printer paper is printable on one side onl

Strona 5 - Table of Contents

iMark Microplate Absorbance Reader Instruction Manual 7 Software Overview Capabilities The iMark Microplate Reader has on-board software tha

Strona 6

iMark Microplate Absorbance Reader Instruction Manual 8 Instrument Functions Calculations The Microplate Reader uses Beer's Law to calc

Strona 7 - Introduction

iMark Microplate Absorbance Reader Instruction Manual 9 The first time the instrument is turned on, or after a battery failure, the followin

Strona 8

iMark Microplate Absorbance Reader Instruction Manual 10 Report Types Two types of reports can be generated; End-point protocol, and Kinetic

Strona 9

iMark Microplate Absorbance Reader Instruction Manual 11 5. Cutoff report The Cutoff report provides a qualitative report of the relative ma

Strona 10 - Keypad Guide

iMark Microplate Absorbance Reader Instruction Manual 12 The result absorbance value of the formula calculation and the gray zone value that

Strona 11 - Instrument Setup

iMark Microplate Absorbance Reader Instruction Manual 13 9. TeSeE Screening Report Analysis of the TeSeE screening assay results can be don

Strona 13 - Software Overview

iMark Microplate Absorbance Reader Instruction Manual 14 Protocol Security Filters Date Set Lab name Cutoff Report Limit STDs Mode Mapping Ki

Strona 14 - Instrument Functions

iMark Microplate Absorbance Reader Instruction Manual 15 Kinetic Protocol Reports Four types of Kinetic protocol reports can be generated: a

Strona 15

iMark Microplate Absorbance Reader Instruction Manual 16 .Func key to switch from [ABC] to [abc] to [sym] key to move cursor .Func key to

Strona 16 - Report Types

iMark Microplate Absorbance Reader Instruction Manual 17 Screen by Screen Procedures Initial Startup 01:

Strona 17

iMark Microplate Absorbance Reader Instruction Manual 18 Configuring the System NOTE: To return to the previous screen, use the back/left ar

Strona 18

iMark Microplate Absorbance Reader Instruction Manual 19 1:400nm 5:650nm 2:450nm 6:.

Strona 19

iMark Microplate Absorbance Reader Instruction Manual 20 Printing Reports and Protocol information Print

Strona 20 - End-point Analysis Protocol

iMark Microplate Absorbance Reader Instruction Manual 21 Memory Recall Operation 01 20/05

Strona 21 - Kinetic Protocol Reports

iMark Microplate Absorbance Reader Instruction Manual 22 Editing the Kinetic Protocol Sele

Strona 22 - Kinetic Analysis Protocol

iMark Microplate Absorbance Reader Instruction Manual 23 Kit name for #01 »G.A.P. TEST IgG« ↑

Strona 23 - Screen by Screen Procedures

i Warranty Statement This warranty may vary outside of the continental United States. Contact your local Bio-Rad office for the exact terms of your

Strona 24 - Configuring the System

iMark Microplate Absorbance Reader Instruction Manual 24 Checkmark Value Setting (Administrator only)

Strona 25

iMark Microplate Absorbance Reader Instruction Manual 25 Editing End Point Protocol Upper

Strona 26 - Adjusting LCD Contrast

iMark Microplate Absorbance Reader Instruction Manual 26 Cutoff Setting Procedure Cutoff Setting Menu This menu is entered by choosing &quo

Strona 27 - Memory Recall Operation

iMark Microplate Absorbance Reader Instruction Manual 27 b. Cutoff Control Selection of Single/Ranged Cutoff Control This menu screen se

Strona 28 - Editing the Kinetic Protocol

iMark Microplate Absorbance Reader Instruction Manual 28 Coefficient for Cutoff Formula 12 The Numerical keys and the Decimal point key are

Strona 29 - Kinetic Protocol Menu

iMark Microplate Absorbance Reader Instruction Manual 29 Standard Setting Procedure Standard Curve Setting Menu This menu screen is entered

Strona 30 - Max. CV% setting

iMark Microplate Absorbance Reader Instruction Manual 30 b. Curve Fit Setting Curve Fit In this screen, there are two choices to set the cur

Strona 31 - Editing End Point Protocol

iMark Microplate Absorbance Reader Instruction Manual 31 c. Recall STD Curve Setting Recall Setting of Standard Curve In this screen, ther

Strona 32 - Cutoff Setting Procedure

iMark Microplate Absorbance Reader Instruction Manual 32 Mode Setting Procedure Mode Setting Menu This menu screen is entered by choosing t

Strona 33 - Single cutoff

iMark Microplate Absorbance Reader Instruction Manual 33 Plate Map Setting Procedure Select Mapping Mode Menu This menu screen is entered b

Strona 34

ii Regulatory Notices Electro Magnetic Compatibility: This instrument is designed to meet the Class-A emissions and immunity levels of the EN 61326 p

Strona 35 - Standard Setting Procedure

iMark Microplate Absorbance Reader Instruction Manual 34 Acceptable Number Ranges for each well type: 1. Blank and Empty wells do not use n

Strona 36 - Graph Axis

iMark Microplate Absorbance Reader Instruction Manual 35 Warning and Error of Automatic Mapping: Warning screen: If the total number of wel

Strona 37 - Right arrow key

iMark Microplate Absorbance Reader Instruction Manual 36 Instrument Maintenance Caution: Electrical shock hazard! Always disc

Strona 38 - Mode Setting Procedure

iMark Microplate Absorbance Reader Instruction Manual 37 Troubleshooting and Error Messages The iMark Microplate Reader constantly monitors

Strona 39 - Plate Map Setting Procedure

iMark Microplate Absorbance Reader Instruction Manual 38 Wells have color, but absorbance values seem low. a. Incorrect filter used for me

Strona 40 - Automatic Mapping

iMark Microplate Absorbance Reader Instruction Manual 39 Instrument Specifications Computer interface USB 2.0 Plate shaking 3 speeds (low,

Strona 43

Life ScienceGroup07-0816 0108 Sig 120710013301i Rev A US/EG Bio-RadLaboratories, Inc. Web site www.bio-rad.com USA 800 4BIORAD Australia

Strona 44

iii Table of Contents Introduction ... 1 Description

Strona 45 - Instrument Specifications

iv Screen by Screen Procedures... 17 Initial Startup ...

Strona 46

iMark Microplate Absorbance Reader Instruction Manual 1 Introduction Description The iMark™ Microplate Absorbance Reader (catalog

Strona 47

iMark Microplate Absorbance Reader Instruction Manual 2 Catalog # Description 168-1130 iMark Microplate Absorbance Reader with built-i

Strona 48 - Laboratories, Inc

iMark Microplate Absorbance Reader Instruction Manual 3 External Features Release latch for rear

Komentarze do niniejszej Instrukcji

Brak uwag