Strona 1 - Instruction Manual

Bio-Scale™Mini Profinity eXact™Cartridges, 1 and 5 mlInstruction ManualCatalog #732-4646732-464810011164A.qxp 11/19/2007 9:54 AM Page I

Strona 2 - Table of Contents

Table 4. Buffer composition.Bind/wash buffer* 100 mM sodium phosphate, pH 7.2Elution buffer* 100 mM sodium phosphate,100 mM sodium fluoride, pH 7.2Reg

Strona 3 - Introduction

supernatant to a clean tube. Remove 50 µl ofthe supernatant, and label the tube "Soluble".3. Resuspend the insoluble pellet in 500 µl ofbin

Strona 4 - Product Information

Section 7Preparation of E. coli LysateFor E. coli cultures expressing medium to high levels ofProfinity eXact-tagged proteins, (≥10% of total protein)

Strona 5 - Profinity eXact cartridges

Purification Protocol1. Equilibrate the cartridge with 10 column volumes(CV) of bind/wash buffer at 3 ml/min (10 ml/min).2. Load the sample lysate a

Strona 6 - Chromatography Systems

Section 9Scaling UpBio-Scale Mini cartridges are available in 1 ml and 5 ml cartridge formats. The Profinity eXact resin isalso available in 10 ml bot

Strona 7

Note: The resin may also be cleaned with 0.1 M NaOH. Limit exposure time to 3 hoursand immediately neutralize with 5 CV ofbind/wash buffer. Regenerati

Strona 8 - Connection to Medium

Problem Possible Cause SolutionPrecipation during Binding capacity of Load less samplepurification cartridge exceededProtein aggregation Include deter

Strona 9

Section 13ReferencesRuan, B et al. Engineering subtilisin into a fluoride-triggered processing protease useful for one-steppurification. Biochemistry

Strona 10 - Buffers and Methods

Profinity eXact™vectors, tags, and resins are exclusively licensed under patent rights of PotomacAffinity Proteins. This product is intended forresear

Strona 11 - Protocol

Table of ContentsSection 1...Introduction ...1Section 2 Product Information...2Section 3

Strona 12 - Preparation of E. coli Lysate

Section 1IntroductionBio-Scale Mini cartridges are convenient, disposable,prepacked chromatography cartridges. Patented*column design assures leak-fre

Strona 13 - Purification Protocol

Table 1. Bio-Scale Mini Profinity eXact cartridge specifications.Sizes 1 ml and 5 ml bed volumesDimensions 1 ml: 40 mm length x 5.6 mm inner diamete

Strona 14 - Regenerating, Cleaning

Table 3. Buffer and chemical compatibilities forProfinity eXact cartridges.ReagentGroup Description StabilityTriggering Ions F-, Cl-, N3-, NO2-, CO2-D

Strona 15

Section 3Connection toLow-PressureChromatography SystemsBio-Scale Mini cartridges are ideal for use with Bio-Rad's BioLogic™ LP chromatography sy

Strona 16 - Troubleshooting Guide

Fig. 2. Connecting to an MV-6 valve.3. Connect the inlet of the cartridge to the maleluer fitting on the MV-6 sample inject valve (seeFigure 2). If n

Strona 17

Section 4Connection to Medium and High-PressureChromatography SystemsBio-Scale Mini cartridges can be connected to anyliquid chromatography system, pr

Strona 18

4.3 FPLC SystemsThe luer to M6 adaptor fittings kit (catalog #732-0111)provides fittings necessary to connect the Bio-ScaleMini cartridge to the M6 f