Maintenance – Basic Machine
360
Pos: 30.32 /BA/ Wartung/Selbstf ahrer/Grundm aschine/Verteilerge triebe @ 0\ mod_11972987 17806_78.doc @ 17418
15.7 Transfer gearbox
1
22
3
BMII-203
Fig. 312:
Note
Use only gearbox oil (synthetic DIN 51502-PGLP) and dispose of used oil
properly.
Oil level check:
Time interval: before every use
Unscrew the inspection screw (2)
Oil level up to bore hole
If necessary, top up oil (synthetic DIN 51502-PGLP)
Screw the check screw (2) back in.
Oil change:
Change the oil after the first 30 to 50 operating hours. Thereafter, ever 500 hours (but at
least once a year)
Screw out the screw plug (3).
Collect the used oil in a suitable drip pan
Screw in the screw plug (3)
Top up the oil (1) (oil level up to hole (2))
Capacity: 6,0 l
Pos: 30.33 /BA/-----Seitenu mbruch------ @ 0\mod_119617 5311226_0.do c @ 4165