18.6 Troubleshooting
Jam in the system or at a connected lubrication point.
Unscrew the outlet screw connections from the main distributor to the subdistributor one
after the other. If lubricant suddenly exits under pressure when one of the outlet screw
connections is loosened, the connected subdistributor is blocked. If lubricant does not exit
from any of the outlet screw connections, the main distributor is blocked. Clean the main
distributor or replace it.
Reinstall the outlet screw connections.
Loosen the outlet screw connections on the blocked subdistributor. If lubricant suddenly
exits under pressure when unscrewing one of the outlet screw connections, the
connected lubrication point is blocked. If lubricant does not exit from any of the outlet
screw connections, the subdistributor is blocked. Clean the blocked subdistributor and
replace it if required.
Remove the blockage at the lubrication point.
Note
For more information on the maintenance of the central lubricating system,
please refer to the operating instructions on the central lubricating system
(Vogel).
Pos: 37 /BA/-----Seitenumbru ch------ @ 0\mod_11961 75311226_0.doc @ 4165
Przeglądanie stron 400
1 2 ... 396 397 398 399 400 401 402 403 404 405 406 ... 484 485

Komentarze do niniejszej Instrukcji

Brak uwag