BIO RAD 400-0174 Instrukcje Operacyjne Strona 469

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 485
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 468
Error Messages
Possible cause Check Remedy
KMC1
Message Meaning
Auger monitoring mode activated even
though there is no auger present
Deactivate auger monitoring mode in the
display
V-belt not tightened Check the V-belt
Perform work diagnostics
Short circuit/broken cable in the wiring
for speed sensor
Check wiring
Speed sensor defective Check speed sensor and replace, if and
when necessary
Distance from sensor to metal
Check distance
Error: Slip, worm drive
right
Slip auger right1405
Distance from sensor to metal
Check distance
Auger monitoring mode activated even
though there is no auger present
Deactivate auger monitoring mode in the
display
V-belt not tightened Check the V-belt
Perform work diagnostics
Short circuit/broken cable in the wiring
for speed sensor
Check wiring
Speed sensor defective Check speed sensor and replace, if and
when necessary
Distance from sensor to metal Check distance
Mower has gone out of the "Mow/ready" setting
Setting for sensor or metal link Check distance
Position sensor defective Check position sensor and replace if
necessary
Error: Slip, worm drive
left
Slip auger left1406
1408 Leave position
mowing unit right
Error - Mower position
sensor right – mower not
in work or ready position